13923464030 0755-81715045   Welcome to Dong Xing refrigeration Electrical Co., Ltd. Official website!
Air-cooled box type industrial chiller

Air-cooled scroll chiller (multi-head)

 Can be customized acid-proof, anti-corrosion, frequency conversion, explosion-proof. The refrigeration heart adopts fully-sealed, low-noise, low-vibration, high-efficiency and power-saving imported brand-name compressors. All electrical control adopts imported brand-name originals. The heat exchanger adopts a shell-and-tube condenser with high heat exchange efficiency and easy cleaning and maintenance.

Online consultingThe national hotline
0755-81715045

Air-cooled box chiller

The refrigeration heart adopts fully-sealed, low-noise, low-vibration, high-efficiency and power-saving imported brand-name compressors. All electrical control adopts imported  brand-name originals. The heat exchanger adopts a shell-and-tube condenser with high heat exchange efficiency and easy cleaning and maintenance.

Energy saving and economy: The digital electronic thermostat can accurately        control the temperature of cold water between +3°C and 50°C, thereby controlling the normal operation of the unit and ensuring that the unit saves energy. The assembly of all units, the filling and debugging of internal wiring refrigerants are all done in the factory , This model can be ordered for cooling and heating dual purpose.

Safe operation: The machine body is equipped with a compressor delay start protector, over-current electrical appliances, high and low voltage protectors, fuse plugs, and electronic time  protection safety valves to ensure the normal operation of the unit.

Condenser:

*The air-cooled condenser adopts steel tube sleeve aluminum fin heat exchanger, single-circuit and multi-circuit design and manufacture, and the coil heat exchange area is larger  than the general standard design, the surface wind speed is uniform, the heat exchange is stable, and the  efficiency is lasting.

*Using high-efficiency threaded steel pipes, the two ends of the cover can be interchanged to change the direction of the water pipe, the water pipe process has multiple loops, each  condenser is matched with the compressor capacity, and the straight-through water pipe is easy to clean and  maintain


Air-cooled chiller (1) Specifications/SPECIFICACATIONS 
ParameterModelDX-1/2ADX-01ADX-02ADX-03ADX-04ADX-05ADX-06ADX-08AD 
Cooling CapacityKw50Hz/60Hz1.531.792.943.445.676.638.399.8210.912.7513.9516.3216.919.7721.825.51 
 
Kcal/h50Hz/60Hz13161540252829584872570172168442937410968119901402814530170001874821935 
 
Total inputKW0.681.312.63.64.55.56.68.6 
Maximum Running CurrentA4.1815.88.810.913.41620.9 
Power SupplyVolt1N-220V 50Hz/60Hz3N-380V/415V 50Hz/60Hz 
 
RefrigerantNameR22 
FillKg0.60.81.82.73.54.353.5x2 
Control typeCapillary Tube 
CompressorTypeHermetic RotaryHermetic Scroll or Piston 
Power MotorKw0.550.751.52.2533.754.53x2 
Air Flowm3/h8001000200030004000500060008000 
Chilled WaterFlowm3/h0.260.310.510.590.971.141.441.681.872.192.42.812.913.413.754.39 
 
Tankm30.0220.0280.0380.0380.0650.0650.110.11 
In/Out pipe sizeG1/2"G1/2"G3/4"G3/4"G3/4"G1"G1"G1"-1/2" 
PumpPower MotorKw0.3750.3750.550.550.550.750.750.75 
PressureKPa180180250242242290290290 
DimensionLengthmm600600820945945103512001470 
Widthmm400400460550550610650710 
Heightmm940940117013701370138514801700 
WeightKg4560120130160170250270 
 

Note:

1. The cooling capacity is calculated based on the ice water inlet                temperature of 12°C and the outlet temperature of 7°C; the cooling water inlet temperature of 30°C and                the outlet temperature of 35°C.             Nominal cooling capacity conditions: chilled water in 12℃,out7℃;                cooling water in 30℃,out35℃.

2. Specifications are subject to change without notice for further                improvement.

 
Air-cooled chiller (two) specifications/SPECIFICACATIONS  
ParameterModelDX-10ADDX-12ADDX-15ADDX-20ADDX-25ADDX-30ADDX-40ADDX-50ADDX-60AD 
Cooling CapacityKw50Hz/60Hz28.0132.7833.7939.5344.1551.6559.0869.1271.7283.9187.2102.02113.58132.89135.49158.52181.68218.02 
 
Kcal/h 50Hz/60Hz24089281842905933999379654441950805594426168372169749928774197675114280116521136330156249187499 
 
Total inputKW1113.31722.827.733.742.851.168.8 
Maximum Running CurrentA26.732.341.355.463.176.897.5116.5143.1 
Power SupplyVolt3N-380V/415V 50Hz/60Hz 
 
RefrigerantNameR22 
FillKg4.3x25x26.5x28.5x210.5x212.5x217x220.5x224.9x2 
Control typeCapillary TubeExternally balanced thermal power expansion valve With hermetic gyral              or piston  
CompressorTypeFully enclosed scroll or piston With hermetic gyral or piston  
Power MotorKw3.75x24.5x25.5x27.5x29.4x211.3x215x218.8x222.5x2 
Air Flowm3/h100001200015000200002500030000400004800066000 
ChilledWaterFlowm3/h4.825.645.816.87.68.8910.1611.8912.3414.441517.5519.5322.8523.327.2730.5236.63 
 
Tankm30.1880.1880.2850.2850.4050.4050.610.610.7 
In/Out pipe sizeG1-1/2"G1-1/2"G2"G2"G2-1/2"G2-1/2"G3"G3"G3" 
PumpPower MotorKw1.51.51.52.22.24444 
PressureKPa205205205220220250250250250 
DimensionLengthmm147514601800196020802080230023003556 
Widthmm71580089094010001000122022002200 
Heightmm169517801880196020552055231022102210 
WeightKg350370520590790880110012801420 
 

Remark:

1. The cooling capacity is calculated based on the ice water inlet                temperature of 12°C and the outlet temperature of 7°C; the cooling water inlet temperature of 30°C and                the outlet temperature of 35°C.

 
Customer service
contact

tel

13923464030

Time

Monday to Saturday

tel

0755-81715045

Qr code