DX-A series air-cooled heat pump chillers are widely used in newly built and rebuilt large and small industrial and civil building air-conditioning projects, such as hotels, apartments, hotels, office buildings, shopping malls, theaters, factories, hospitals, etc. Especially for projects that have high requirements on noise and surrounding environment, and it is inconvenient to install boilers and cooling towers or cooling water pumps, it is an ideal choice.
Adopt Taiwan Hanbell/German Bitzer screw compressor, or Japan Daikin scroll compressor;
heat exchanger adopts imported high-efficiency heat exchanger;
automatic temperature control is intelligent; the
most reliable unit protection;
users only need to configure external Connect the pipeline to the unit and connect the electrical silk circuit to put it into use.
Specifications of DX-A series air-cooled heat pump unit:
model | DX-03A | DX-05A | DX-08A | DX-10A | DX-12A | DX-15A | DX-20A | ||
using electric | 3Ф-50HZ-380V | ||||||||
Cooling capacity | KW | 9 | 15.2 | 21.2 | 27.5 | 34.8 | 42.6 | 56.5 | |
Kcal/h | 7820 | 13070 | 18230 | 23650 | 29930 | 36630 | 48590 | ||
Heating capacity | KW | 10.7 | 18.1 | 25.2 | 32.7 | 41.3 | 50.6 | 67.1 | |
Kcal/h | 9200 | 15530 | 21650 | 28120 | 35500 | 43510 | 57720 | ||
Power consumption | KW | 2.65 | 4.27 | 6.55 | 8.65 | 11.05 | 13.5 | 17.6 | |
Chilled water | m3/h | 1.4 | 2.3 | 3.8 | 5 | 6.2 | 7.3 | 9.6 | |
compressor | Type | Fully enclosed scroll/piston | |||||||
Start method | Direct start sequence | ||||||||
Output power (KW) | 2.3 | 3.8 | 5.6 | 7.5 | 9.4 | 11.3 | 15 | ||
Refrigerant | Type | R-22 | |||||||
way to control | Temperature sensing type external pressure equalizing expansion valve | ||||||||
Filling amount (Kg) | 2 | 3.6 | 5.1 | 6.5 | 8.2 | 9.6 | 13.3 | ||
Water side exchanger | Type | Shell and tube | |||||||
Diameter B | PT1″ | PT1-1/2″ | PT2″ | ||||||
Air heat exchanger | Type | Internal thread copper tube fin type | |||||||
Surface area/row M2 | 0.62/3R | 0.62/4R | 1.16/3R | 1.16/4R | 1.92/3R | 2.28/3R | 3.06/3R | ||
Axial fan | Type | Low noise axial flow | |||||||
Air volume CMM | 65 | 110 | 150 | 195 | 220 | 265 | 390 | ||
Power KW | 0.25 | 0.37 | 0.55 | 0.55 | 0.75 | 1.1 | 0.55×2 | ||
protective device | 高低压开关,防冻保护,可溶栓/安全阀,过载保护装置,线圈过热保护器,温度自动保护, 开关等。 | ||||||||
外型尺寸 | 长mm | 920 | 920 | 1200 | 1200 | 1500 | 1500 | 1860 | |
宽mm | 850 | 850 | 1050 | 1050 | 1100 | 1100 | 1220 | ||
高mm | 1300 | 1300 | 1450 | 1450 | 1580 | 1580 | 1700 | ||
机组重量 | Kg | 160 | 190 | 300 | 330 | 390 | 430 | 600 |
型号 | DX-25A | DX-30A | DX-35A | DX-40A | DX-45A | DX-50A | DX-60A | |
使用电源 | 3Ф-50HZ-380V | |||||||
制冷量 | KW | 65.2 | 84.2 | 97.5 | 113.1 | 125.2 | 139.3 | 167.1 |
Kcal/h | 56070 | 72410 | 83850 | 97260 | 107660 | 119790 | 143700 | |
制热量 | KW | 77.5 | 99.6 | 115.2 | 134.3 | 148.5 | 164.9 | 197.2 |
Kcal/h | 66750 | 85675 | 98212 | 114369 | 126830 | 140855 | 168560 | |
消耗电力 | KW | 21.7 | 26.8 | 30.5 | 35.2 | 40.9 | 43.3 | 52.9 |
冷冻水量 | m3/h | 12.1 | 14.3 | 16.8 | 19 | 21.5 | 23.8 | 28.5 |
压缩机 | 型式 | 全封闭涡旋式/活塞式 | ||||||
启动方式 | 顺序直接启动 | |||||||
输出功率(KW) | 18.8 | 22.5 | 26.3 | 30 | 33.8 | 37.5 | 45 | |
冷媒 | 型式 | R-22 | ||||||
控制方式 | 感温式外部均压膨胀阀 | |||||||
充填量(Kg) | 15.8 | 20.4 | 23.6 | 27.8 | 30.3 | 33.6 | 40.2 | |
水侧交换器 | 型式 | 壳管式 | ||||||
管径B | PT2-1/2″ | PT3″ | ||||||
空气换热器 | 型式 | 内螺纹铜管翅片式 | ||||||
表, 面积/排 M2 | 3.80/3R | 4.52/3R | 5.36/3R | 6.08/3R | 6.82/3R | 7.54/3R | 39.02/3R | |
轴流风扇 | 型式 | 低噪轴流式 | ||||||
风量CMM | 440 | 530 | 620 | 760 | 820 | 880 | 1060 | |
功率KW | 0.75×2 | 1.1×2 | 1.1×2 | 1.5×2 | 2.2×2 | 0.75×4 | 1.1×4 | |
保护装置 | 高低压开关,防冻保护,可溶栓/安全阀,过载保护装置,线圈过热保护器,温度自动保护开关等。 | |||||||
外型尺寸 | 长mm | 1860 | 2250 | 2400 | 2680 | 2800 | 2450 | 2560 |
宽mm | 1220 | 1300 | 1300 | 1350 | 1350 | 2300 | 2300 | |
高mm | 1700 | 1850 | 1850 | 1900 | 1900 | 1900 | 1900 | |
机组重量 | Kg | 680 | 950 | 1070 | 1150 | 1380 | 1510 | 1680 |